Página 1 - Backbone

53-1002180-0727 June 2014Brocade DCX 8510-8BackboneHardware Reference Manual

Página 2

• Brocade Supplemental Support augments your existing OEM support contract, providing directaccess to Brocade expertise. For more information, contact

Página 3 - Contents

}5. Login to the chassis and execute the switchcfgpersistentdisable command on the main switchand other logical switches. The switchcfgpersistentdisa

Página 4

Replacing the WWN card and WWN bezel (logo plate)Complete the following steps to replace the bezel and the WWN cards.Follow electrostatic discharge (E

Página 5

Blade Transceiver Auto-negotiate/Fixed Speeds supported(xGbps)FC8-64 mSFP Auto negotiate 2, 4, and 8.FC16-32 and FC16-48 SFP+ Auto negotiate 2, 4, 8,

Página 6

blade. Refer to the illustration for the mSFP transceiver for the basic appearance of the 16 Gbpstransceiver.FIGURE 30 Replacing an optical transceive

Página 7 - Document conventions

Transceivers are keyed so that they can only be inserted with the correct orientation. If a transceiverdoes not slide in easily, ensure that it is cor

Página 8 - Notes, cautions, and warnings

Transceivers are keyed so that they can only be inserted with the correct orientation. If a transceiverdoes not slide in easily, ensure that it is cor

Página 9 - Brocade resources

Replacing a QSFP transceiverComplete the following steps to replace a QSFP transceiver.1. If the QSFP transceiver is being replaced, grasp the bail of

Página 10 - Document feedback

NOTEFor the Brocade DCX 8510 Backbones, an off-the-shelf QSFP cable up to 50 meters long can be usedas an ICL cable.NOTEFor the Brocade DCX 8510 Backb

Página 11 - About This Document

Time and items requiredThe replacement procedure for an ICL cable takes less than five minutes. Only a replacement ICLcable is required for this proce

Página 12 - What’s new in this document

FIGURE 36 QSFP cable connections for Brocade DCX 8510 chassis (sample configuration)1. Chassis 1 - DCX 8510-82. Chassis 2 - DCX 8510-4The DCX 8510 cha

Página 13 - Brocade DCX 8510-8 Overview

About This Document● Supported hardware and software... 11● What’s new

Página 14

FIGURE 37 DCX 8510 core/edge ICL topologyThe DCX 8510 chassis can also be connected in a full mesh configuration as shown in the followingfigure. Alth

Página 15

FIGURE 38 DCX 8510 full mesh ICL topologyBrocade DCX 8510-8 chassis removal and replacementThis section describes how to remove and replace the Brocad

Página 16

6. Installing components into the new chassis on page 1177. Downloading the configuration on page 1188. Verifying correct operation of system on page

Página 17 - Brocade DCX 8510-8 blades

Recording critical Brocade DCX 8510-8 and SAN informationAll commands must be entered from a CLI session (Telnet or serial) to the active CP blade unl

Página 18

NOTEIf you are using the Virtual Fabric feature, you should run configupload -vf before running theconfigupload command to save the logical switch con

Página 19 - Reliability

Power Consume Factor: -3Factory Part Num: 60-0001501-07Factory Serial Num: FT02X805BE2Manufacture: Day: 26 Month: 3 Year: 20

Página 20 - Security

Stopping blade 1 Shutting down the blade...Stopping blade 2 Shutting down the blade...Stopping blade 8 Shutting down the blade...Broadcast message

Página 21 - Network manageability

DANGERUse safe lifting practices when moving the product.DANGERA completely empty Brocade DCX 8510-8 chassis weighs approximately 37.3 kg (82.2 lb) an

Página 22

6. Replace the port blades or filler panels (Port, application, and encryption blade removal andreplacement on page 76 and Blade filler panel removal

Página 23

password: xxxxxxxxswitch:admin>2. Enter the slotShow -m command and verify that all the installed cards are detected and that theirstatus is operat

Página 24

What’s new in this document12 Brocade DCX 8510-8 Backbone Hardware Reference Manual53-1002180-07

Página 25

Reconnecting the system to the network and fabricRefer to the cable routing information recorded in Cable routing table on page 121 for the followings

Página 26

020f00 021fda 021fdc 021fe0 021fe15 Nx_Ports in the Fabric}switch:admin> switchshowswitchName: rsl8-st03-dcx-01<output truncated>switch:admi

Página 27 - Port numbering

Cable routing table for Brocade DCX 8510-8 (64 ports shown) (Continued)TABLE 16 Slot/port Cable labels Connected device Slot/port of device101112131

Página 28

Cable routing table for Brocade DCX 8510-8 (64 ports shown) (Continued)TABLE 16 Slot/port Cable labels Connected device Slot/port of device363738394

Página 29 - Cable management

Cable routing table for Brocade DCX 8510-8 (64 ports shown) (Continued)TABLE 16 Slot/port Cable labels Connected device Slot/port of device6263Remov

Página 30 - High-density cabling

Specifications● General specifications...125● System a

Página 31 - Installing ICL cables

System architectureThe following table describes the system architecture of the Brocade DCX 8510-8.System architecture TABLE 18 Feature DescriptionF

Página 32

System architecture (Continued)TABLE 18 Feature DescriptionPort types FC8-32E port blade: F_Port, E_Port, Ex_Port, and M_Port.FC8-48E port blade: F_

Página 33

System size and weightThe weight of the Brocade DCX 8510-8 can vary considerably depending on the combination ofblades installed. Use the following ta

Página 34

System FRU weights (Continued)TABLE 20 FRU WeightFC8-64 port blade 3.36 kg (7.4 lb) without mediaFC16-32 port blade 2.8 kg (6.2 lb) without mediaFC1

Página 35

Brocade DCX 8510-8 Overview● Brocade DCX 8510-8 features... 13● B

Página 36 - Configuring the IP addresses

Environmental requirementsThe following table lists the environmental operating ranges for the Brocade DCX 8510-8. Therequirements for non-operating c

Página 37

The QSFP transceiver part numbers supported on the core blades are different from the QSFPtransceiver part numbers supported on the FC16-64 port blade

Página 38 - Setting the domain ID

You can calculate your power requirements by combining the power draws for the various blades andfan units in your configuration. While you may use fe

Página 39 - Setting the date and time

Power supply requirementsTABLE 24 Demand Power supplies @ 110 VAC (nominal) Power supplies @ 220 VAC (nominal)Up to 1000W 2 21000W-2000W 4 2Greater

Página 40 - Synchronizing local time

Power cord types (international) (Continued)TABLE 25 Plug style NEMA5-20P125VonlyUSA,Canada,Mexico,otherlocationsNEMAL6-20USA,Canada,Mexico,otherloc

Página 41 - Verifying the PID mode

Power cord types (international) (Continued)TABLE 25 Plug style NEMA5-20P125VonlyUSA,Canada,Mexico,otherlocationsNEMAL6-20USA,Canada,Mexico,otherloc

Página 42

Power cord types (international) (Continued)TABLE 25 Plug style NEMA5-20P125VonlyUSA,Canada,Mexico,otherlocationsNEMAL6-20USA,Canada,Mexico,otherloc

Página 43

DANGERDisconnect the power cord from all power sources to completely remove power from the device.DANGERIf the installation requires a different power

Página 44 - Managing cables

Supported optics, speeds, cables, and distances (Continued)TABLE 26 TransceivertypeFormfactorSpeed Multimodemedia (62.5microns)(OM1)Multimodemedia (

Página 45

Qualified cables for mSFP connections for the FC8-64 high density port blade (Continued)TABLE 27 Description Length Corning part number Molex partnu

Página 46

Brocade DCX 8510-8 hardware componentsThe Brocade DCX 8510-8 features a modular and scalable mechanical construction that allows a widerange of flexib

Página 47 - Monitoring System Components

FIGURE 39 QSFP to QSFP standard cables1. QSFP MTP connectorFIGURE 40 QSFP-SFP/LC Break-out/Split-out cables1. QSFP MTP connector2. SFP+ LC connectorsW

Página 48

Application and Encryption Blades● Introduction...

Página 49

NOTEThe port diagram on the front panel uses the abbreviations GE for 1 GbE ports and 10GE for 10 GbEports.NOTEThe 10 GbE SFPs used in the FX8-24 blad

Página 50

‐ The Link Cost is equal to the sum of all established/low metric (or currently active) circuits’MAX rates in the tunnel.‐ Fabrics connected through F

Página 51

Limitations of FCOE10-24 bladeThe following limitations have to be considered when using FCOE10-24 application blade with FabricOS 7.3.0, on the DCX 8

Página 52 - Blade illustrations

Diagnostics and Troubleshooting● Introduction...

Página 53

Environmental status and maintenance commands TABLE 28 Command Information displayedsensorShow Temperature readings for the port bladesTemperature r

Página 54

Any errors detected during POST are written to the system log, which is accessible through theerrShow command. For information about error messages, r

Página 55

TroubleshootingThe following table provides a list of issues, possible causes, and recommended actions.Troubleshooting the Brocade DCX 8510-8TABLE 29

Página 56

Troubleshooting the Brocade DCX 8510-8 (Continued)TABLE 29 Issue Possible cause Recommended actionLEDs on one or morecomponents are changingrapidly

Página 57

‐ The 16-Gbps QSFPs supported on FC16-64 prot blade auto-negotiate at 4, 8, and16 Gbps.‐ The 16-Gbps QSFPs based inter-chassis link (ICL) on the core

Página 58

Troubleshooting the Brocade DCX 8510-8 (Continued)TABLE 29 Issue Possible cause Recommended actionBlades might be faulty. Enter the slotShow command

Página 59

Port Numbering TemplatePrint or copy the following templates in this appendix and use them to document the port numberingpattern for the Brocade DCX 8

Página 60

FIGURE 41 CR16-8 core blade1. Port map2. QSFP ports 12-15 (bottom to top)3. QSFP ports 8-11 (bottom to top)4. QSFP ports 0-3 (bottom to top)5. QSFP po

Página 61

External port to slotShow port mapping for core blades (Continued)TABLE 30 External port number slotShow port numbers External port number slotShow

Página 62

1. Blade power LED2. Blade status LED3. FC ports 24-314. Port and trunking group map5. FC ports 16-236. FC ports 0-77. FC ports 8-15FIGURE 43 FC8-48E

Página 63

FIGURE 44 FC8-64 port blade1. Blade status LED2. Blade power LED3. Port 634. Port 305. Port 61 status LED6. Port 29 status LED7. FC ports 32-63 (botto

Página 64

FIGURE 45 FC16-32 port blade1. Blade power LED2. Blade status LED3. FC ports 24-314. Port and trunking group map5. FC ports 16-236. FC ports 0-77. FC

Página 65

FIGURE 46 FC16-48 port blade1. Blade power LED2. Blade status LED3. FC ports 24-474. FC ports 0-23Port Numbering TemplateBrocade DCX 8510-8 Backbone H

Página 66

FIGURE 47 FC16-64 port blade1. QSFP ports 8-15; FC ports 32-63 (bottom to up)2. QSFP ports 0-7; FC ports 0-31 (bottom to up)Port Numbering Template158

Página 67

FIGURE 48 FS8-18 encryption blade1. Gigabit Ethernet ports GE0-GE12. Smart card port3. Fibre Channel ports 0-15Port Numbering TemplateBrocade DCX 8510

Página 68

FIGURE 1 Port side of the Brocade DCX 8510-8 (sample configuration)1. Exhaust vent2. Core switch blade (CR16-8)3. Control processor blade (CP8)4. FC16

Página 69

FIGURE 49 FX8-24 extension blade1. 10 GbE ports 0-12. 1 GbE ports 0-33. 1 GbE ports 4-94. FC ports 6-115. FC ports 0-56. Blade Power LED7. Blade Statu

Página 70

FIGURE 50 FCOE10-24 FCoE blade1. 10-GbE CEE ports 12-232. 10-GbE CEE ports 0-113. Power LED4. Status LEDPort Numbering TemplateBrocade DCX 8510-8 Back

Página 71

Port Numbering Template162 Brocade DCX 8510-8 Backbone Hardware Reference Manual53-1002180-07

Página 72

Regulatory Statements● Regulatory compliance...163● Env

Página 73 - ESD precautions

Power-cord notice (Japan, Denan)DANGERNever use the power cord packed with your equipment for other products.BSMI statement (Taiwan)Warning:This is Cl

Página 74 - Removing a chassis door

Canadian requirementsThis Class A digital apparatus meets all requirements of the Canadian Interference-Causing EquipmentRegulations, ICES-003 Class A

Página 75 - Replacing a chassis door

Regulatory compliance standards (Continued)TABLE 31 Country Standards Agency Certifications andMarkingsTaiwan (PS only) CNS 14336(94) or latest CNS

Página 76

Caution and Danger Notices● Cautions...

Página 77

PRECAUCIÓN Antes de conectar un cable en cualquier puerto, asegúrese de descargar la tensión acumuladaen el cable tocando la superficie de conexión a

Página 78 - Removing a blade

Electrical dangersDANGERMake sure that the power source circuits are properly grounded, then use the power cordsupplied with the device to connect it

Página 79 - Replacing a blade

FIGURE 2 Nonport side of the Brocade DCX 8510-8 (sample configuration)1. WWN bezel (logo plate - WWN card behind)2. Power supply3. Blower assemblyBroc

Página 80 - Removing a filler panel

PELIGRO Para desconectar completamente la corriente del instrumento, desconecte el cordón decorriente de todas las fuentes de corriente.DANGERIf the i

Página 81 - Replacing a filler panel

DANGER Un commutateur Brocade DCX 8510-8 complet (huit cartes de port FC16-64, 512 ports) pèseenviron 161.2 kg et requiert un dispositif de levage hyd

Página 82 - Faulty CP blade indicators

Danger Notices172 Brocade DCX 8510-8 Backbone Hardware Reference Manual53-1002180-07

Página 83

Index10 GbE ports 141Aairflow, requirement 130altitude, requirement 130ambient temperature, requirement 130ANSI protocol 125application bladedetermini

Página 84

troubleshooting 148configure command 38, 41configuring IP address 36core switch bladedetermining status 65replacing 92CP bladedetermining status 63rep

Página 85

replacing 97FS8-18 blade 141FX8-24 blade 141GGbE ports 141Hhigh availability 19humidity, requirement 130Iinstallationitems required 24SFP 41installati

Página 86

QQSFP cablesinstalling 106replacing 106QSFPsas inter-chassis links 43QSFP transceivers 106Rrack space requirement 24regulatory compliance 163reliabili

Página 87

chassis power 148configuration data 148CP blade 148domain IDs 148Ethernet link speed 148FRUs 148general 145IP addresses 148LEDs 148port blade 148seria

Página 88

178 Brocade DCX 8510-8 Backbone Hardware Reference Manual53-1002180-07

Página 89 - Completing the replacement

Blades available for the Brocade DCX 8510-8 (Continued)TABLE 1 Description Name FunctionBrocade DCX8510-8 core switchbladeCR16-8 The CR16-8 blade co

Página 90

Blades available for the Brocade DCX 8510-8 (Continued)TABLE 1 Description Name FunctionFCIP extensionbladeFX8-24 The FX8-24 blade enables FCIP func

Página 91

© 2014, Brocade Communications Systems, Inc. All Rights Reserved.Brocade, the B-wing symbol, Brocade Assurance, ADX, AnyIO, DCX, Fabric OS, FastIron,

Página 92

ServiceabilityThe Brocade DCX 8510-8 provides the following features to enhance and ensure serviceability:• Modular design with hot-swappable componen

Página 93 - Identifying power supplies

• DH-CHAP• SSHv2 (using AES, 3DES, RSA)• HTTPS (using AES)• SNMPv3• FC-SP• Secure RPC• Secure file copy (SCP)• Telnet disable• Telnet timeout• IP filt

Página 94 - Removing a power supply

Network manageability22 Brocade DCX 8510-8 Backbone Hardware Reference Manual53-1002180-07

Página 95 - Replacing a power supply

Installation of the Brocade DCX 8510-8● Time and items required...

Página 96 - Removing a blower assembly

Installation tasks, time, and items required (Continued)TABLE 2 Installation task Time estimate Items requiredInstalling power cables andpowering on

Página 97 - Replacing a blower assembly

• 200 - 240 VAC, 50-60 Hz (two branch circuits) - recommended for high availability and maximumblade usage when configured with 192 16 Gbps ports (fou

Página 98

NOTEThe Brocade DCX 8510-8 packaging does not incorporate a wood pallet and palletbrackets. The chassis sits on top of a plastic shipping tray.2. Use

Página 99

NOTEFor information about the SFP+, mSFP, and QSFP transceivers that are qualified for the Brocade DCX8510-8, go to http://www.brocade.com/downloads/d

Página 100

Blade Port numbering Trunking port groupsFC8-32E portblade• 0 through 15 from bottom to top on theleft set of ports.• 16 through 31 from bottom to top

Página 101

Blade Port numbering Trunking port groupsFX8-24 blade Ports are numbered in groups:• The FC ports are numbered from 0through 11 in two vertical column

Página 103 - Replacing an SFP+ transceiver

CAUTIONBefore plugging a cable into to any port, be sure to discharge the voltage stored on the cableby touching the electrical contacts to ground sur

Página 104 - Replacing an mSFP transceiver

Installing ICL cablesRefer to Inter-chassis link (ICL) cable removal and replacement on page 106 for the procedure to installthe ICL QSFP cables.Insta

Página 105 - Removing a QSFP transceiver

Installing ICL cables32 Brocade DCX 8510-8 Backbone Hardware Reference Manual53-1002180-07

Página 106 - Replacing a QSFP transceiver

Logging In and Configuring the Brocade DCX 8510-8● Configuring the Brocade DCX 8510-8...

Página 107

FIGURE 4 Configuration tasksEstablishing a serial connection to the Brocade DCX 8510-8To establish a serial connection to the console port on the Broc

Página 108 - Possible ICL configurations

NOTEThe CONSOLE port is intended primarily for the initial setting of the IP address and for servicepurposes.3. Access the Brocade DCX 8510-8 using a

Página 109 - 53-1002180-07

swDir:admin>2. (Optional) Modify passwords. To skip modifying the password, press Ctrl+C. For more informationon passwords, refer to the Fabric OS

Página 110

Enter the information at the prompts.This is a sample IP configuration:swDir:admin> ipaddrset -chassisEthernet IP Address [0.0.0.0]: 192.168.1.1Eth

Página 111

The Brocade DCX 8510-8 can be accessed through a remote connection using the command linevia Telnet or any of the management tools, such as Web Tools

Página 112

3. Enter y at the Fabric parameters prompt:Fabric parameters (yes, y, no, n): [no] y4. Enter a unique domain ID:Domain: (1.239) [1] 35. Complete the r

Página 113

Customizing a chassis name... 38Setting the domain ID...

Página 114

Use timezone_fmt to set the time zone by Country/City or by time zone ID, such as PST.The following example shows how to change the time zone to US/Ce

Página 115

Verifying the PID modeBefore connecting the Brocade DCX 8510-8 to the fabric, verify that the WWN-based persistent portidentifier (PID) feature on the

Página 116

Installing SFP+ and mSFP transceivers and cablesComplete the following steps to install SFP-type optical transceivers.NOTEmSFP transceivers are compat

Página 117

Installing QSFP transceivers and cablesFollow these steps to install the QSFPs and cables in the FC16-64 port blades and the 16-Gbps coreblades. In th

Página 118 - Downloading the configuration

260 3 4 1 ------ -- 16G No_Module FC261 3 5 1 ------ -- 16G No_Module FC262 3 6 1 ------ --

Página 119

NOTERefer to "Cabling Best Practices" (available at http://www.brocade.com ) for cable managementguidelines.For the procedure to install the

Página 120

Powering off the Brocade DCX 8510-8Perform the following steps to power off the Brocade DCX 8510-8.1. Shut down the Brocade DCX 8510-8 using the sysSh

Página 121 - Cable routing table

Monitoring System Components● Monitoring overview...

Página 122

12 1 12 780c00 -- -- Offline VE Disabled (Persistent) 13 1 13 780d00 -- -- Offline VE 14 1 14 780e00

Página 123

802 3 50 782280 -- N8 No_Module FC 803 3 51 782380 id N8 No_Light FC 804 3 52 782480 -- N8 No_Modul

Página 124

Removing a core switch blade (CR16-8)... 90Replacing a core switch blade (CR16-8)...

Página 125 - Specifications

398 5 14 ------ id 16G No_SigDet FC 399 5 15 ------ id 16G No_SigDet FC 400 5 16 ------ id 16G No_SigDe

Página 126 - System architecture

Time Alive: 14 daysTime Awake: 0 daysCP BLADE Slot: 6Header Version: 2Power Consume Factor: -40Factory Part Num:

Página 127

FAN Unit: 1Header Version: 2Power Consume Factor: -126Factory Part Num: 60-1000384-09Factory Serial Num: AGB0652E0HAManufacture:

Página 128 - System blade and FRU weights

This section illustrates the following port blades:• The FC8-32E port blade.• The FC8-48E port blade.• The FC8-64 port blade.• The FC16-32 port blade.

Página 129 - Facility requirements

3. Fibre Channel port4. Port status LEDFIGURE 6 FC8-48E port blade1. Power LED2. Status LED3. Fibre Channel port4. Port status LEDMonitoring System Co

Página 130 - Environmental requirements

FIGURE 7 FC8-64 port blade1. Status LED2. Power LED3. Fibre Channel port4. Port status LEDMonitoring System ComponentsBrocade DCX 8510-8 Backbone Hard

Página 131 - Power specifications

FIGURE 8 FC16-32 port blade1. Power LED2. Status LED3. Fibre Channel port4. Port status LEDMonitoring System Components56 Brocade DCX 8510-8 Backbone

Página 132

FIGURE 9 FC16-48 port blade1. Power LED2. Status LED3. Fibre Channel port4. Port status LEDMonitoring System ComponentsBrocade DCX 8510-8 Backbone Har

Página 133 - Power cords

FIGURE 10 FC16-64 port blade1. Blade Power LED2. Blade Status LED3. Port status LED for FC port 364. QSFP port 9; FC ports 36-39 (bottom to up)Monitor

Página 134

FIGURE 11 FS8-18 encryption blade1. Power LED2. Status LED3. Fibre Channel port4. Port status LEDMonitoring System ComponentsBrocade DCX 8510-8 Backbo

Página 135

Qualified cables for the FC8-64 port blade... 138Cable types supported on the FC16-64 port blade...

Página 136 - Power-cord notice

FIGURE 12 FX8-24 extension blade1. Power LED2. Status LED3. GbE port 64. GbE port 6 LED5. 10-GbE port 06. 10-GbE port 0 LED7. Port mapMonitoring Syste

Página 137 - Data transmission ranges

FIGURE 13 FCOE10-24 FCoE blade1. Power LED10 GbE2. Status LED3. 10 GbE FCoE port 94. 10 GbE FCoE port 9 LED5. 10 GbE FCoE port 196. 10 GbE FCoE port 1

Página 138

Port and application blade LED descriptions TABLE 4 LED purpose Color Status Recommended actionPower LED Steady green Blade is enabled. No action re

Página 139

Port and application blade LED descriptions (Continued)TABLE 4 LED purpose Color Status Recommended actionSteady amber Port is receiving light orsig

Página 140

FIGURE 14 Control processor blade (CP8)1. Power LED2. Status LED3. USB LED4. USB port5. Console port (Serial)6. Ethernet port (Mgmt IP)7. Ethernet por

Página 141 - FX8-24 blade

CP blade LED descriptions TABLE 5 LED purpose Color Status Recommended actionPower Steady green CP blade is on. No action required.No light (LED is

Página 142

1. Check the LED indicators on the core switch blade. The LED patterns may temporarily changeduring POST and other diagnostic tests. For information a

Página 143 - FCOE10-24 blade

CR blade LED descriptions TABLE 6 LED purpose Color Status Recommended actionPower Steady green CR16-8 blade is on. No action required.No light (LED

Página 144

1. Check the LED indicator on the power supply. The LED patterns may temporarily change duringPOST and other diagnostic tests; for information about h

Página 145

8510-8 supplier to order replacement parts. Both physically absent or faulty could also be the resultof the power supply not being properly seated.FIG

Página 146

Preface● Document conventions...7● Brocade resource

Página 147 - Diagnostics

Blower assembly LED descriptions (Continued)TABLE 8 LED purpose Color Status Recommended actionFlashing amber (on 1/2second, then off 3.5seconds)Fan

Página 148 - Troubleshooting

Messages that may indicate WWN card failure (Continued)TABLE 9 Type of message Sample error messageWWN unit removal was detected.<timestamp>,

Página 149

3. Port blade Status (above) and Power (below) LEDs4. Slot numbersMonitoring System Components72 Brocade DCX 8510-8 Backbone Hardware Reference Manual

Página 150

Removal and Replacement Procedures● Introduction...

Página 151 - Port Numbering Template

Chassis door removal and replacementNOTEThe chassis door must be installed to ensure the Brocade DCX 8510-8 meets EMI and otherregulatory certificatio

Página 152

Replacing a chassis doorComplete the following steps to reinstall the door.1. Align the holes in the door with the ball studs on the chassis.2. Push t

Página 153

FIGURE 20 Removal and replacement of the cable management combReplacing a cable management combComplete the following steps to replace the cable manag

Página 154

CAUTIONIf you do not install a module or a power supply in a slot, you must keep the slot filler panel inplace. If you run the chassis with an uncover

Página 155

• Small form-factor pluggable (SFP+, mSFP, or QSFP) transceivers (as needed)• Optical and copper cables (as needed)NOTEFor information about the trans

Página 156

11.Open the ejectors by rotating them toward the center of the blade face. Pull the blade out of thechassis using the ejectors.12.If the blade is not

Página 157

Convention Descriptionvalue In Fibre Channel products, a fixed value provided as input to a commandoption is printed in plain text, for example, --sho

Página 158

DANGERFor safety reasons, the ESD wrist strap should contain a series 1 megaohm resistor.NOTEAn FA4-18i application blade and the Brocade DCX 8510-8 m

Página 159

FIGURE 22 Removal and replacement of the blade filler panelReplacing a filler panelDo not leave a slot empty. This will adversely affect cooling of th

Página 160

Control processor blade (CP8) removal and replacementThis document describes how to remove and replace a control processor (CP8) blade. Each chassisha

Página 161

• The haShow command indicates an error.• The clock is inaccurate, or the CP blade does not boot up or shut down normally.• Any of the following messa

Página 162

The following example shows the results of the firmwareshow command when the firmwareversions on the two CP blades are not the same. Note the warning

Página 163 - Regulatory Statements

FIGURE 23 Removal and replacement of the control processor blade (CP8)Replacing a control processor blade (CP8)NOTERead all of the instructions for re

Página 164 - CE statement

1. Open the ejector handles to approximately 45 degrees. Orient the CP blade so that the handles aretoward you and the flat metal side is on your left

Página 165 - German statement

If you are using a USB device to download the firmware, skip to Downloading firmware from a USBdevice on page 88. If the firmware on the standby CP bl

Página 166 - China RoHS

NOTEThe time stamp on the co-CPU may not be in sync with the main CPU on the blade. This is not acause for concern.5. Log back in to the standby CP bl

Página 167 - Caution and Danger Notices

The system is coming up, please wait...Fri Jun 18 14:53:13 2010: Doing firmwarecommit now.Please wait ...Fri Jun 18 14:55:27 2010: Firmware commit

Página 168 - Danger Notices

Brocade resourcesVisit the Brocade website to locate related documentation for your product and additional Brocaderesources.You can download additiona

Página 169 - Electrical dangers

4. Pack the faulty CP blade in the packaging provided with the new CP blade, and contact the switchsupplier to determine the return procedure.5. Repla

Página 170

DANGERFor safety reasons, the ESD wrist strap should contain a series 1 megaohm resistor.NOTEThe CR16-8 blade is compatible only with the Brocade DCX

Página 171

FIGURE 24 Removal and replacement of the core switch blade (CR16-8)Replacing a core switch blade (CR16-8)Follow electrostatic discharge (ESD) precauti

Página 172

NOTEThe Brocade DCX 8510-8continues to operate while a core switch blade is being replaced.Complete the following steps to replace the core switch bla

Página 173

FIGURE 25 Power supply identification1. Power supply 1 (PS1)2. Power supply 2 (PS2)3. Power supply 3 (PS3)4. Power supply 4 (PS4)Removing a power supp

Página 174

FIGURE 26 Removal and replacement of the power supplyReplacing a power supplyTo replace a power supply, complete the following steps.1. If you are not

Página 175

7. Verify that the power LED on the power supply displays a steady green light.8. If you are installing two new power supplies in a DCX or DCX 8510-8

Página 176

FIGURE 27 Removal and replacement of the blower assemblyReplacing a blower assemblyComplete the following steps to replace the blower assembly in a ch

Página 177 - WWN card

replaced, you need to power-down the chassis, and then both the WWN cards must be replaced as amatched pair.Time and items requiredAllow approximately

Página 178

Removing the WWN card and WWN bezel (logo plate)When both the replacement WWN cards have been received, complete the following steps to removethe beze