Brocade Network OS Message Reference v4.1.1 Manual do Utilizador Página 208

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 478
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 207
192 Network OS Message Reference
53-1003227-01
FSPF-1005
8
FSPF-1005
Message Wrong Section Id <section number>, should be <section number>, input port = <port
number>.
Message Type LOG
Severity ERROR
Probable Cause Indicates that an incorrect section ID was reported from the specified input port. The section ID is part of
the fabric shortest path first (FSPF) protocol and is used to identify a set of switches that share an
identical topology database.
Recommended
Action
This switch does not support a non-zero section ID. Any connected switch from another manufacturer
with a section ID other than 0 is incompatible in a fabric of Brocade switches. Disconnect the
incompatible switch.
FSPF-1006
Message FSPF Version <FSFP version> not supported, input port = <port number>.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the fabric shortest path first (FSPF) version is not supported on the specified input port.
Recommended
Action
Update the FSPF version by running the firmware download command. All current versions of the
Network OS support FSPF version 2.
FSPF-1007
Message ICL triangular topology is broken between the neighboring RBridges: <RBridge
number> and <RBridge number>. Please fix it ASAP.
Message Type LOG
Severity ERROR
Probable Cause Indicates that the inter-chassis link (ICL) triangular topology is broken and becomes linear. It may cause
frame drop or performance slowdown.
Recommended
Action
Investigate the ICLs and reconnect the switches to form a triangular topology.