Network OS Message Reference 211
53-1003227-01
FW-1039
8
FW-1039
Message <Label>, is above high boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the receive power value of the small form-factor pluggable (SFP) transceiver has risen
above the high boundary. The receive performance area measures the amount of incoming laser to help
you determine if the SFP transceiver is in good working condition or not. If the counter often exceeds the
threshold, the SFP transceiver is deteriorating.
Recommended
Action
Replace the SFP transceiver before it deteriorates.
FW-1040
Message <Label>, is between high and low boundaries(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
Message Type LOG
Severity INFO
Probable Cause Indicates that the receive power value of the small form-factor pluggable (SFP) transceiver has changed
from a value outside of the acceptable range to a value within the acceptable range. The receive
performance area measures the amount of incoming laser to help you determine if the SFP transceiver is
in good working condition or not. If the counter often exceeds the threshold, the SFP transceiver is
deteriorating.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.
FW-1042
Message <Label>, is below low boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the transmit power value of the small form-factor pluggable (SFP) transceiver has fallen
below the low boundary. The transmit performance area measures the amount of outgoing laser to help
you determine if the SFP transceiver is in good working condition or not. If the counter often exceeds the
threshold, the SFP transceiver is deteriorating.
Recommended
Action
Verify that the optical components are clean and functioning properly. Replace deteriorating cables or
SFP transceivers. Check for damage from heat or age.