Network OS Message Reference 283
53-1003227-01
MCST-1004
8
MCST-1004
Message NSM error: <op> (<reason>) for VLAN <vid> port <port>.
Message Type DCE
Severity ERROR
Probable Cause Indicates that the multicast subsystem (mcast_ss) has encountered an error during a network service
module (NSM) event.
Recommended
Action
Reload or power cycle the switch.
MCST-1005
Message Message error: Invalid message type <type> expecting <value1> or <value2> or
<value3>.
Message Type DCE
Severity ERROR
Probable Cause Indicates that the type of the message received from the driver is invalid.
Recommended
Action
Reload or power cycle the switch.
MCST-1006
Message Message error: <op> (<reason>)Invalid message length <length> expecting
<length1>.
Message Type DCE
Severity ERROR
Probable Cause Indicates that the length of the message received from the driver is invalid.
Recommended
Action
Reload or power cycle the switch.
Vista de página 298