Network OS Message Reference 219
53-1003227-01
FW-1424
8
FW-1424
Message Switch status changed from <Previous state> to <Current state>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the switch is not in a healthy state. This occurred because of a policy violation.
Recommended
Action
Execute the show system monitor command to determine the policy violation.
FW-1425
Message Switch status changed from <Bad state> to HEALTHY.
Message Type LOG
Severity INFO
Probable Cause Indicates that the switch status has changed to a healthy state. This state change occurred because a
policy is no longer violated.
Recommended
Action
No action is required.
FW-1426
Message Switch status change contributing factor Power supply: <Number Bad> bad, <Number
Missing> absent.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the switch is not in a healthy state. This occurred because the number of faulty or missing
power supplies is greater than or equal to the policy set by the system-monitor command.
Recommended
Action
Replace the faulty or missing power supplies.